| Buy |
PDF |
Photo |
Part Number |
Manufacturer |
Description |
Packaging | Series | Connector Type | Number of Positions | Shell Size - Insert | Shell Size, MIL | Mounting Type | Termination | Fastening Type | Orientation | Ingress Protection | Shell Material, Finish | Contact Finish | Features |
|
 |
 |
D38999/20FB35SA |
Souriau Connection Technology |
CONN RCPT 13POS WALL MNT W/SCKT |
Bulk | Military, MIL-DTL-38999 Series III | Receptacle, Female Sockets | 13 | 11-35 | B | Panel Mount, Flange | Crimp | Threaded | A | - | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
FGG.1K.307.CLAK75 |
LEMO |
CONN INLINE PLUG 7PIN SLD CUP |
Bulk | 1K | Plug, Male Pins | 7 | 307 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
FGG.2K.306.CLAK95 |
LEMO |
CONN INLINE PLUG 6PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 6 | 306 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS27467T15F19SB |
Souriau Connection Technology |
CONN PLUG 19POS STRAIGHT W/SCKT |
Bulk | Military, MIL-DTL-38999 Series I | Plug, Female Sockets | 19 | 15-19 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | B | Environment Resistant | Aluminum, Nickel Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD42 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
PFA.2B.312.CLLD82 |
LEMO |
CONN PNL MNT RCPT 12SKT SLD CUP |
Bulk | 2B | Receptacle, Female Sockets | 12 | 312 | - | Free Hanging (In-Line); Panel Mount, Bulkhead - Rear Side Nut | Solder Cup | Push-Pull | A | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
ACT90MD18SA-3025 |
TE Connectivity |
CONN RCPT 18POS FLANGE W/SKT |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Female Sockets | 18 | 15-18 | - | Panel Mount, Flange | Crimp | Threaded | A | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD52 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
PFA.2B.312.CLLD92Z |
LEMO |
CONN PNL MNT RCPT 12SKT SLD CUP |
Bulk | 2B | Receptacle, Female Sockets | 12 | 312 | - | Free Hanging (In-Line); Panel Mount, Bulkhead - Rear Side Nut | Solder Cup | Push-Pull | A | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD72Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
JBXEC2G16FSSDS |
Souriau Connection Technology |
CONN RCPT 16POS PNL MNT SKT |
Bulk | JBX | Receptacle, Female Sockets | 16 | 2 | - | Panel Mount, Bulkhead - Front or Rear Side Nut | Solder Cup | Push-Pull | G | IP67 - Dust Tight, Waterproof | Brass, Chrome over Nickel | Gold | Shielded |
|
 |
 |
D38999/26JJ4HA |
TE Connectivity |
CONN PLUG 56POS STRGHT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III, ACT | Plug, Male Pins | 56 | 25-4 | J | Free Hanging (In-Line) | Crimp | Threaded | A | Environment Resistant | Composite, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
ACT96WJ4PA |
TE Connectivity |
CONN PLUG 56POS STRGHT W/PINS |
Bulk | MIL-DTL-38999 Series III, ACT | Plug, Male Pins | 56 | 25-4 | - | Free Hanging (In-Line) | Crimp | Threaded | A | Environment Resistant | Composite, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
JBXFC3G14MSSDSMR |
Souriau Connection Technology |
CONN PLUG 14POS CABLE PIN RA |
Bulk | JBX | Plug, Male Pins | 14 | 3 | - | Free Hanging (In-Line), Right Angle | Solder Cup | Push-Pull | G | IP40 | Brass, Chrome over Nickel | Gold | Cable Clamp, Shielded |
|
 |
 |
FGG.2B.308.CYCD82Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
- |
 |
CIR020R28-21PF80T39 |
ITT Cannon |
CIR 37C 37#16 PIN RECP |
| * | | | | | | | | | | | | |
|
 |
 |
FGG.2B.308.CYCD92Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
JBXFC3G14MSSDSR |
Souriau Connection Technology |
CONN PLUG 14POS CABLE PIN RA |
Bulk | JBX | Plug, Male Pins | 14 | 3 | - | Free Hanging (In-Line), Right Angle | Solder Cup | Push-Pull | G | IP40 | Brass, Chrome over Nickel | Gold | Cable Clamp, Shielded |
|
 |
 |
CA3106R28-11PB |
ITT Cannon |
CONN PLUG 22POS INLINE W/PINS |
Bulk | MIL-DTL-5015, CA-B | Plug, Male Pins | 22 | 28-11 | - | Free Hanging (In-Line) | Solder Cup | Reverse Bayonet Lock | N (Normal) | IP67 - Dust Tight, Waterproof | Aluminum Alloy, Olive Drab Cadmium Plated | Silver | - |
|
 |
 |
JBXFC3G10MCSDSMR |
Souriau Connection Technology |
CONN PLUG 10POS CABLE PIN RA |
Bulk | JBX | Plug, Male Pins | 10 | 3 | - | Free Hanging (In-Line), Right Angle | Crimp | Push-Pull | G | IP40 | Brass, Chrome over Nickel | Gold | Cable Clamp, Shielded |
|
 |
 |
FGG.2K.303.CLAC65Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
JBXFC3G10MCSDSR |
Souriau Connection Technology |
CONN PLUG 10POS CABLE PIN RA |
Bulk | JBX | Plug, Male Pins | 10 | 3 | - | Free Hanging (In-Line), Right Angle | Crimp | Push-Pull | G | IP40 | Brass, Chrome over Nickel | Gold | Cable Clamp, Shielded |
|
- |
 |
CIR030-20-27SX-F80 |
ITT Cannon |
CIR 14C 14#16 FR SKT RECP |
| * | | | | | | | | | | | | |
|
 |
 |
FGG.2K.303.CLAC80Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
- |
 |
CIR030-20-27SY-F80 |
ITT Cannon |
CIR 14C 14#16 FR SKT RECP |
| * | | | | | | | | | | | | |
|
 |
 |
HGP.2S.302.CLLPV |
LEMO |
CONN PNL MNT RCPT 2SKT SLD CUP |
Bulk | 2s | Receptacle, Female Sockets and Male Pins | 2 | 302 | - | Panel Mount, Bulkhead - Rear Side Nut | Solder Cup | Push-Pull | Keyed | IP68 - Dust Tight, Waterproof | Brass, Chrome Plated | Gold | Shielded, Vacuumtight |
|
 |
 |
ACT90WD35SN |
TE Connectivity |
CONN RCPT 37POS FLANGE W/SKT |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Female Sockets | 37 | 15-35 | - | Panel Mount, Flange | Crimp | Threaded | N (Normal) | Environment Resistant | Composite, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
D38999/26WE26HN |
Souriau Connection Technology |
CONN PLUG 26POS STRAIGHT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III | Plug, Male Pins | 26 | 17-26 | E | Free Hanging (In-Line) | Crimp | Threaded | N (Normal) | - | Aluminum, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
EEG.2B.310.CYP |
LEMO |
CONN PNL MNT RCPT 10SKT CRIMP |
Bulk | 2B | Receptacle, Female Sockets | 10 | 310 | - | Panel Mount, Flange - Front Side Nut | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
ACT94MB35PN-3025 |
TE Connectivity |
CONN RCPT 13POS JAM NUT W/PINS |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Male Pins | 13 | 11-35 | - | Panel Mount, Bulkhead - Front Side Nut | Crimp | Threaded | N (Normal) | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
- |
 |
MS3111F2016S |
Souriau Connection Technology |
CONN RCPT 16POS CBL MNT W/SCKT |
Bulk | Military, MIL-DTL-26482 G Series I, 851 | Receptacle, Female Sockets | 16 | 20-16 | - | Free Hanging (In-Line) | Solder Cup | Bayonet Lock | N (Normal) | - | Olive Drab Cadmium Plated | Gold | Cable Clamp |
|
 |
 |
D38999/24MB35PN |
TE Connectivity |
CONN RCPT 13POS JAM NUT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III, ACT | Receptacle, Male Pins | 13 | 11-35 | B | Panel Mount, Bulkhead - Front Side Nut | Crimp | Threaded | N (Normal) | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
FGG.1K.307.CLAK70 |
LEMO |
CONN INLINE PLUG 7PIN SLD CUP |
Bulk | 1K | Plug, Male Pins | 7 | 307 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
ACT90MG11SB-3025 |
TE Connectivity |
CONN RCPT 11POS FLANGE W/SKT |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Female Sockets | 11 | 21-11 | - | Panel Mount, Flange | Crimp | Threaded | B | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
MS27467T17F8PA |
Souriau Connection Technology |
CONN PLUG 8POS STRAIGHT W/PINS |
Bulk | Military, MIL-DTL-38999 Series I | Plug, Male Pins | 8 | 17-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | A | Environment Resistant | Aluminum, Nickel Plated | Gold | Shielded |
|
 |
 |
FGG.1K.307.CLAK85 |
LEMO |
CONN INLINE PLUG 7PIN SLD CUP |
Bulk | 1K | Plug, Male Pins | 7 | 307 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS27467T15B35PB |
Souriau Connection Technology |
CONN PLUG 37POS STRAIGHT W/PINS |
Bulk | Military, MIL-DTL-38999 Series I | Plug, Male Pins | 37 | 15-35 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | B | Environment Resistant | Aluminum, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD52Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS3471L24-61P |
TE Connectivity |
CONN RCPT 61POS CABLE PIN |
Bulk | Military, MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | N (Normal) | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | - |
|
 |
 |
D38999/24JB2PA |
TE Connectivity |
CONN RCPT 2POS JAM NUT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III, ACT | Receptacle, Male Pins | 2 | 11-2 | B | Panel Mount, Bulkhead - Front Side Nut | Crimp | Threaded | A | Environment Resistant | Composite, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD62 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS3471L24-61PW |
TE Connectivity |
CONN RCPT 61POS CABLE PIN |
Bulk | Military, MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | W | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | - |
|
 |
 |
FGG.2B.308.CYCD62Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS3471L24-61PX |
TE Connectivity |
CONN RCPT 61POS CABLE PIN |
Bulk | Military, MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | X | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | - |
|
 |
 |
ACT94WB2PA-3025 |
TE Connectivity |
CONN RCPT 2POS JAM NUT W/PINS |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Male Pins | 2 | 11-2 | - | Panel Mount, Bulkhead - Front Side Nut | Crimp | Threaded | A | Environment Resistant | Composite, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
FGG.2B.308.CYCD72 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
KPT07A20-24P |
ITT Cannon |
CONN RCPT 24POS W/PIN JAM NUT |
Bulk | MIL-DTL-26482 Series I, KPT | Receptacle, Male Pins | 24 | 20-24 | - | Panel Mount, Bulkhead - Front Side Nut | Solder Cup | Bayonet Lock | N (Normal) | - | Aluminum Alloy, Olive Drab Cadmium Plated | Gold | - |
|
 |
 |
MS3471L24-61PY |
TE Connectivity |
CONN RCPT 61POS CABLE PIN |
Bulk | Military, MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Y | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | - |
|
- |
 |
CIR030-18-19S-F80-T12-15 |
ITT Cannon |
CIR 10C 10#16 (18-20) SKT RECP |
| * | | | | | | | | | | | | |
|
 |
 |
MS3471L24-61PZ |
TE Connectivity |
CONN RCPT 61POS CABLE PIN |
Bulk | Military, MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Z | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | - |
|
 |
 |
FGG.2B.308.CYCD82 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
AFD51-24-61PN |
TE Connectivity |
CONN RCPT 61POS STRGHT W/PINS |
Bulk | MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | N (Normal) | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
KPSE07E12-3SA206 |
ITT Cannon |
CONN RCPT 3POS JAM NUT W/SKTS |
Bulk | MIL-DTL-26482 Series I, KPSE | Receptacle, Female Sockets | 3 | 12-3 | - | Panel Mount, Bulkhead - Front Side Nut | Crimp | Bayonet Lock | N (Normal) | Environment Resistant | Aluminum Alloy, Zinc Plated, Black | Gold | - |
|
 |
 |
FGG.2B.308.CYCD92 |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
AFD51-24-61PW |
TE Connectivity |
CONN RCPT 61POS STRGHT W/PINS |
Bulk | MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | W | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
85136G107P50 |
Souriau Connection Technology |
CONN PLUG 7POS STRAIGHT W/PINS |
Bulk | MIL-DTL-26482, 851 | Plug, Male Pins | 7 | 10-7 | - | Free Hanging (In-Line) | Solder Cup | Bayonet Lock | N (Normal) | - | Olive Drab Cadmium Plated | Gold | Removable Backshell |
|
 |
 |
FGG.2B.308.CYCD99Z |
LEMO |
CONN INLINE PLUG 8PIN CRIMP |
Bulk | 2B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line) | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
AFD51-24-61PX |
TE Connectivity |
CONN RCPT 61POS STRGHT W/PINS |
Bulk | MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | X | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
D38999/24FD35PC |
Souriau Connection Technology |
CONN RCPT 37POS JAM NUT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III | Receptacle, Male Pins | 37 | 15-35 | D | Panel Mount, Bulkhead - Front Side Nut | Crimp | Threaded | C | - | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
FGG.2K.303.CLAC55Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
AFD51-24-61PY |
TE Connectivity |
CONN RCPT 61POS STRGHT W/PINS |
Bulk | MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Y | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
MS3475L16-26S |
TE Connectivity |
CONN PLUG 26POS CABLE SCKT |
Bulk | Military, MIL-C-26482 G Series II, AFD | Plug, Female Sockets | 26 | 16-26 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | N (Normal) | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC75Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
AFD51-24-61PZ |
TE Connectivity |
CONN RCPT 61POS STRGHT W/PINS |
Bulk | MIL-C-26482 G Series II, AFD | Receptacle, Male Pins | 61 | 24-61 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Z | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
MS3475L16-26SW |
TE Connectivity |
CONN PLUG 26POS CABLE SCKT |
Bulk | Military, MIL-C-26482 G Series II, AFD | Plug, Female Sockets | 26 | 16-26 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | W | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC85Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
CA3101E24-9PF80DN |
ITT Cannon |
CONN RCPT 2POS INLINE W/PINS |
Bulk | MIL-DTL-5015, CA | Receptacle, Male Pins | 2 | 24-9 | - | Free Hanging (In-Line) | Crimp | Threaded | N (Normal) | IP65 - Dust Tight, Water Resistant | Aluminum Alloy, Olive Drab Cadmium Plated | Silver | Shrink Boot Adapter |
|
 |
 |
MS3475L16-26SY |
TE Connectivity |
CONN PLUG 26POS CABLE SCKT |
Bulk | Military, MIL-C-26482 G Series II, AFD | Plug, Female Sockets | 26 | 16-26 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Y | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FHG.1B.307.CLAZZ |
LEMO |
CONN R/A PLUG 7PIN SLD CUP |
Bulk | 1B | Plug, Male Pins | 7 | 307 | - | Free Hanging (In-Line), Right Angle | Solder Cup | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
CA3106E22-2SDN |
ITT Cannon |
CONN PLUG 3POS INLINE W/SKTS |
Bulk | MIL-DTL-5015, CA | Plug, Female Sockets | 3 | 22-2 | - | Free Hanging (In-Line) | Solder Cup | Threaded | N (Normal) | IP65 - Dust Tight, Water Resistant | Aluminum Alloy, Olive Drab Cadmium Plated | Silver | Shrink Boot Adapter |
|
 |
 |
HMG.1B.304.CLLP |
LEMO |
CONN PNL MNT RCPT 4SKT SLD CUP |
Bulk | 1B | Receptacle, Female Sockets | 4 | 304 | - | Panel Mount, Flange - Front Side Nut | Solder Cup | Push-Pull | G | IP68 - Dust Tight, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
MS3475L16-26SZ |
TE Connectivity |
CONN PLUG 26POS CABLE SCKT |
Bulk | Military, MIL-C-26482 G Series II, AFD | Plug, Female Sockets | 26 | 16-26 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | Z | Environment Resistant | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
BACC63CT17-6PN |
Souriau Connection Technology |
CONN PLUG 6POS STRAIGHT W/PIN |
Bulk | BACC63, 8D | Plug, Male Pins | 6 | 17-6 | - | Free Hanging (In-Line) | Crimp | Threaded | N (Normal) | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
PHG.2B.307.CLLM42 |
LEMO |
CONN INLINE RCPT 7SKT SLD CUP |
Bulk | 2B | Receptacle, Female Sockets | 7 | 307 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
CA3100E20-16PBF80 |
ITT Cannon |
CONN RCPT 9POS WALL MNT W/PINS |
Bulk | MIL-DTL-5015, CA-B | Receptacle, Male Pins | 9 | 20-16 | - | Panel Mount, Flange | Crimp | Reverse Bayonet Lock | N (Normal) | IP67 - Dust Tight, Waterproof | Aluminum Alloy, Olive Drab Cadmium Plated | Silver | Strain Relief |
|
 |
 |
M83723/78R18086 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | Military, MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 6 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
MS27468T15F18P |
Souriau Connection Technology |
CONN RCPT 18POS JAM NUT W/PINS |
Bulk | Military, MIL-DTL-38999 Series I | Receptacle, Male Pins | 18 | 15-18 | - | Panel Mount, Bulkhead - Front Side Nut | Crimp | Bayonet Lock | N (Normal) | Environment Resistant | Aluminum, Nickel Plated | Gold | - |
|
 |
 |
FFA.3S.303.CLAL72 |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 3S | Plug, Female Sockets and Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | Keyed | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
M83723/78R18087 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | Military, MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 7 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
D38999/26WB35SC |
Souriau Connection Technology |
CONN PLUG 13 POS STRAIGHT W/SCKT |
Bulk | Military, MIL-DTL-38999 Series III | Plug, Female Sockets | 13 | 11-35 | B | Free Hanging (In-Line) | Crimp | Threaded | C | - | Aluminum, Olive Drab Cadmium Plated | Gold | Shielded |
|
 |
 |
FGG.1B.310.GLAD42Z |
LEMO |
CONN INLINE PLUG 10PIN SLD CUP |
Bulk | 1B | Plug, Male Pins | 10 | 310 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP50 - Dust Protected | Polyetheretherketone (PEEK) | Gold | Shielded |
|
 |
 |
M83723/78R18088 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | Military, MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 8 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.1K.307.CLAK80 |
LEMO |
CONN INLINE PLUG 7PIN SLD CUP |
Bulk | 1K | Plug, Male Pins | 7 | 307 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
FHG.1B.308.CYCD42 |
LEMO |
CONN R/A PLUG 8PIN CRIMP |
Bulk | 1B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line), Right Angle | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
M83723/78R18089 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | Military, MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 9 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC15Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
FHG.1B.308.CYCD52 |
LEMO |
CONN R/A PLUG 8PIN CRIMP |
Bulk | 1B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line), Right Angle | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
ACT90MF32SA |
TE Connectivity |
CONN RCPT 32POS FLANGE W/SKT |
Bulk | MIL-DTL-38999 Series III, ACT | Receptacle, Female Sockets | 32 | 19-32 | - | Panel Mount, Flange | Crimp | Threaded | A | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC25Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
FHG.1B.308.CYCD72 |
LEMO |
CONN R/A PLUG 8PIN CRIMP |
Bulk | 1B | Plug, Male Pins | 8 | 308 | - | Free Hanging (In-Line), Right Angle | Crimp | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
DL68G18-08P6-6106 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 6 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC50Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
- |
 |
ECG.2B.434.CJA |
LEMO |
CONN PNL MNT RCPT 4HV(3KV) PIN |
Bulk | 2B | Receptacle, Male Pins | 4 | 434 | - | Panel Mount, Bulkhead - Front Side Nut | Solder Cup | Push-Pull | G | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
DL68G18-08P7-6106 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 7 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
FGG.2K.303.CLAC70Z |
LEMO |
CONN INLINE PLUG 3PIN SLD CUP |
Bulk | 2K | Plug, Male Pins | 3 | 303 | - | Free Hanging (In-Line) | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
EEA.2B.312.CLV |
LEMO |
CONN PNL MNT RCPT 12SKT R/A PCB |
Bulk | 2B | Receptacle, Female Sockets | 12 | 312 | - | Panel Mount, Flange; Through Hole, Right Angle | Solder | Push-Pull | A | IP50 - Dust Protected | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
DL68G18-08P8-6106 |
TE Connectivity |
CONN PLUG 8POS STRGHT W/PINS |
Bulk | MIL-C-83723 Series III | Plug, Male Pins | 8 | 18-8 | - | Free Hanging (In-Line) | Crimp | Bayonet Lock | 8 | IP67 - Dust Tight, Waterproof | Aluminum, Nickel Plated, Electroless | Gold | Shielded |
|
 |
 |
D38999/26MA98PE |
Souriau Connection Technology |
CONN PLUG 3POS STRAIGHT W/PINS |
Bulk | Military, MIL-DTL-38999 Series III | Plug, Male Pins | 3 | 9-98 | A | Free Hanging (In-Line) | Crimp | Threaded | E | Environment Resistant | Composite, Nickel Plated | Gold | Shielded |
|
 |
 |
EEG.0K.302.CLJ |
LEMO |
CONN PNL RCPT THERM CPL PAIR |
Bulk | 0K | Receptacle, Female Sockets | 2 | 302 | - | Panel Mount, Flange - Front Side Nut | Solder Cup | Push-Pull | G | IP66/68 - Dust Tight, Water Resistant, Waterproof | Brass, Chrome Plated | Gold | Shielded |
|
 |
 |
CA3106E14S-7SBF80A176A232 |
ITT Cannon |
CONN PLUG 3POS INLINE W/SKTS |
Bulk | MIL-DTL-5015, CA-B | Plug, Female Sockets | 3 | 14S-7 | - | Free Hanging (In-Line) | Crimp | Reverse Bayonet Lock | N (Normal) | IP67 - Dust Tight, Waterproof | Aluminum Alloy, Black Zinc Cobalt Plated | Gold | Strain Relief |